  1. The images below are self explanatory for the tributary area method. I use this method to find the size of the column in a multistory building
    1 point
  2. @Hussam Afifyyou can manually apply the overturning check, multiply horizontal load (either from wind or seismic) with the distance from the bottom of the footing to get your overturning moment, and then check against the stabilizing moment i.e (weight of the structure + soil above footing multiplied with their respective lever arms.