Jump to content

Leaderboard

Popular Content

Showing content with the highest reputation on 04/27/23 in all areas

  1. If leakage is a serious problem then a waterproof membrane is nearly always prescribed. If a little leakage is OK, then you might consider a perimeter drainage system around the tank and sump pit .
    2 points
  2. Salam Zohair, it ok to have water tank there, just check any column loads which are around the periphery of tank and design walls of the tank for shear, take care to make its foundation joints and other top slab level joints are sealed, any leakage could create serious problems.
    1 point
  3. Dik

    UGWT Location within the Raft

    How far below grade is it founded? How thick is it? Can the UGWT be built into the raft foundation. Can it be expanded in size to minimise the depth and the loads on the tank walls?
    1 point
  4. Salam, In reviewing one etabs model, I found that my retaining wall was assigned membrane, when removed and replaced with shell this negative time period problem resolved. Thank you
    1 point