DEARS; MAY ANY ONE PROVIDE US BY THE PROCEDURE TO MAKE THERMAL ANALYSIS FOR THE VERTICAL ELEMENTS AND SLABS? BY ETABS AND SAFE REGARDS
-
DEARS; IS IT POSSIBLE THAT TWO ADJACENT RAFT FOUNDATIONS TO BE ON DEIFFERENT LEVELS AS 1 METER DIFFERENCE IN LEVEL??. I THINK NO... IF YOU ACCEPT WITH ME WHAT IS POSSIBLE SOLUTIONS? THANKS
-
THANKS ENGNEER YA I GOT IT
-
THANKS TOO MUCH
-
DEARS; WHAT IS THE WIND LOAD AS KN/M2 TO TAKE INTO CONSIDERATIONIN DESINGING BOUNDARY WALL OF HEIGHT 3 M ?
-
Thanks so much . You know !! I am reviewing a project that contains these imaginary combinations !!! So I discovered it has no code reference
-
Thanks so much . May this load combination be in the British code : 1.4Dead+- 1.2 E or 1.4D+-1.2E +1Live
-
Dear Engineers; Is there special load combinations for precast concrete bildings design??
-
Dear engineers; 1. For what we need tie beams ? 2. I mean if I take the first floor's columns' height into consideration in my model ? 3. Will it carry the slab on grade ? 4. In case of Raft then no need for thetie beams since the slab on grade will lay on the raft Yes? Regards
-
Dear Engineers; Is it allowed to use the 2D-plate analysis for the raft?? Because the 2D neglects the inplane forced of the raft, Will it affect the out of plane forces?? if yes then I think it is not accurate for the analysis in presence of earthquake and wind loads coming from the superstructure, Am I right?? Or it just will neglect the results of analysis of in-plane forces without affecting the out of plane forces.? Regards
-
How To Judge The Additional Reinforcement In Safe
mhdhamood replied to mhdhamood's topic in Concrete Design
THANKS SO MUCH -
How To Judge The Additional Reinforcement In Safe
mhdhamood replied to mhdhamood's topic in Concrete Design
Yes . But if we took the average of the three strips will be (14+3+3)/3= 7T16 not 5T16 !!!!!!!!!! how I judge -
Engineers; I have strips in slab designing of 1 meter width ... near the column appeared additional steel to be provided like this: exactly over the column it needed 14T16 right one and left one : 3T16 what is the additional steel shall I put?? because an experienced engineer provided only T16/20 cm ( 5T16/m) is that true???
-
Great brothers his is the greatest forum
-
I want simplicity please!!!! what are you saying .... If a building has corewalls and columns+ beams (MRF system) then I may consider he building acting as building frame system (depending on shear walls ) and using R related . and we may also consider it as dual system and designing the frames and shear walls to resist the base shear. This what I know !!!
-
But here the qustion arises; A building has core walls and columns with flat slab. How I describe this building ?? as a Dual system ot building frame system?
-
Dear all; I was thinking about at the mid support of continuous beam , if we can stop the top steel only distance of development length into the mid support (not to be continuous ) is that possible ?? As I can simpy think; it is possiple cz the steel to work shall be developed from the critical section and that condition here exist. Discuss please Regards
-
But let me add one more thing ; we shall add the axial load and moment carried by the basement wall from the slab. Am I right ?? or we can neglect the axial load and just taking the moment due to fixity consideration
-
thanks so much guys..... This is the best forum
-
ooooooh very nice explanation thanks I got more one information
-
Thanks so much our engineer
-
Dear All; I have a problem in design for punchings for the attached case.Since the column near an opening : 1. Do I need always to deduct the ineffective length as I draw in fig.1, whatever the length of the opening??? 2. why not consider the opening like a free edge then the effective punching perimeter will be good and taller ??? 3. If I need to provide a drop panel and I have 8 meters spans that means it will be 8/3 meter its dimenstions or I can provide lesser dimensions like 1meter ??since I need it to resis punching
-
Thank you dear engineer
- 7 replies
-
- minimum reinforcement ratio
- min steel ratio
-
(and 1 more)
Tagged with:
-
Dears; The minimum steel ratio =0.0018 is for one face or for the 2 faces of the section (top & bottom)?? As far as I know that 0.0018 is for the face exposed to tension (not the 2 faces). Since the Mat suffers tension at top and bottom of the section at the same section so we provide 0.0018 for 2 faces . Am I right??? Regards
- 7 replies
-
- minimum reinforcement ratio
- min steel ratio
-
(and 1 more)
Tagged with: