  1. this reiforcement need to provide to resist diagonal tension cracks. normally it is required in large structures, where tension is high, no need for small structures
  2. what is normal design practice in lahore for foundation design if there is very low bearing capacity, is it deep foundation or shallow foundation?
  3. temperature load can be assigned to the members that affected with the temperature variation only (like exterior members)
  4. You need to provide expansion joint at podium near to all three tower and analyze them separately. Because each tower has different time period Based on there geometry and loading so the lateral forces will be different
  5. yes, in this case most of lateral load carrying by shear wall, so your beam column have lesser lateral forces, thats why the reinforcement has decreased in these members
  6. So what you will do, will you going to change the Pakistan Building Code?
  7. Thanks for your response. I can work in other locations if suitable
  8. http://www.sepakistan.com/applications/core/interface/file/attachment.php?id=65 pile design link
  9. I am having 16 year of experience totally in structural design . I worked 8 year in Pakistan and 8 years in Saudi Arabia. I came from Saudi Arabia in June 2017. Since then I am searching job. I request the members if somebody have job in their office please let me know.
  10. this deflection shows in Etabs is global deflection, this will increase due to axial and lateral deformation of the members globally, if you check deflection individuallly with respect to each floor value than u will find the same deflection
  11. I have worked so many project in khi and I lived near this area, based on my experienced I suggested these value
  12. Please tell me the location of the site in karachi. I will tell u the appropriate. B.c value
  13. Rana, What is the solution if I cannot If it is not possible to do all these solution, what shall he do, because this is the local pressure at one side only. the average total pressure may be very less than the allowable pressure
  14. You cannot provide fix support under wall. You have to provide spring soil modulus under the raft. Increase area of foundation and thickness of raft under the shear wall to reduce the bearing capacity values
  15. Stiffness modifiers are used to account for cracking in concrete. It is the nature of concrete to crack and hence, it is important to modify its stiffness to accurately get deflections and moments
  16. Dear BAZ, What really needs to do additionally in ETAB model
×
×