Mat cannot be part of inertial forces. The slabs with in basements can participate depending upon the level of grade on both sides of building, the stiffness of basement walls or other below-grade vertical members and type of soil. You can take a look at this document: asce-003_asce_7-10_commentar.pdf https://cdn.ymaws.com/www.nibs.org/resource/resmgr/bssc/asce-003_asce_7-10_commentar.pdf
-
I have not understood that why are you thinking that there is some discrepancy. As far as the ultimate design is concerned, I believe you mean: strength based design. This is the only procedure that we follow. No body uses working stress design procedure. As far as your wall is concerned, it is not necessary that every structural component that you will encounter in actual structures will be subjected to a moment which is at-least grater than the cracking moment. If the demand is less than what is require to cause stresses-inelastic-section-cracked situation, the strength design is not applicable on the cross-section. However, the section must have minimum reinforcement to initiate ductile failure as per applicable code.
-
I never went through this situation. Having said, there are other options within the nonlinear settings proforma to reduce the time taken by the software like step size, number of iterations per search and likewise. One can play with them to see their effect.
-
There are number of ways to deal with the walls. First, make sure that you have satisfied the force-demand on the wall. As you have said, ETABS gave you the distribution of reinforcement in the wall. This distribution should satisfy the demand for flexure. For shear, the reinforcement suggested by the ETABS may not be adequate. You need to confirm it by adopting the capacity-based design approach. The requirement of boundary element is there to ensure that your wall does not crush, or reinforcement doesn't buckle, due to compression. For that, ETABS only specifies the region where you need to confine the concrete as per ACI code's direction, which depends on the location of neutral axis. Make sure to confine this region; no extra reinforcement is needed if you have provided the vertical reinforcement suggested by the software. However, in order to satisfy the confinement criteria, you may need to add additional vertical reinforcement and thus you may deviate from the arrangement suggested by the software. This can increase the moment capacity of your wall, and thus the shear demand (Capacity-design approach). There is another approach, simplified one, in which engineer only considers the vertical reinforcement within the boundary region to be effective as far as in-plane moment is concerned. In that case Asfy x moment arm should be equal to in-plane demand of moment. Where d is the moment-arm created by boundary zones on either ends of the wall, and As is the total area of steel in boundary zone.
-
You can to study the "anchorage in concrete" guidelines provided by the ACI 318 to see if is possible to do that. Yes, these post-installed epoxy-fixed bars are durable. You can attach the overhang with steel.
- 3 replies
-
- epoxy
- epoxy rebars
-
(and 1 more)
Tagged with:
-
Tension only cable bracings failing in compression in etabs
Badar (BAZ) replied to callmeismail's topic in Steel Design
it may be due to a software bug. PMM does not necessary mean that the software is designing for compression. Anyway you can always perform your own checks if you are confident about the analysis results. -
Modelling of Retaining walls and BackStay Effect
Badar (BAZ) replied to Gerald Elusen's topic in Concrete Design
You must include them in the model. In addition to resisting out-of-plane forces, in the form of soil pressure, it will resist in-plane forces even if the base is located at higher level due to back-stay effect. You can find the approach to tackle it in following documents. https://www.structuremag.org/wp-content/uploads/C-StructPractices-Tocci-June121.pdf http://www.tallbuildings.org/PDFFiles/2017-LATBSDC-CRITERIA_Final_w_2018_ Supplements_FINAL_20180320.pdf -
How to get reaction of shear wall in ETABS..?
Badar (BAZ) replied to siju simon's topic in Concrete Design
Label the wall elements as pier and spandrels, and get out their forces in text file once you are done with analysis. -
Yes, if you want to scale the base shear obtained from RSA with respect to the value from Equivalent static procedure.
-
Scaling is done in most softwares by changing the value of "g". You can change the scaling factor to bring it down to the required range.
-
Develop Stress Strain Curve (Mander) using SAP2000
Badar (BAZ) replied to Fatima Khalid's topic in Concrete Design
If you set loading type as nonlinear and set the load application control as displacement, then check if you are able to get convergence in your model. I tried to model material nonlinearity of RCC in a different context, I couldn't get the desired result in SAP 2000. -
You need to consult ACI 313-16. Ensiled material load to be treated as live load
-
Read the manual of your software
-
how to compute "effective mass coefficient ε"?
Badar (BAZ) replied to Zargham Amir Dar's topic in Seismic Design
Use Appendex B -
Stiffness modifiers Prestressed Concrete
Badar (BAZ) replied to Ayman Trad's topic in Seismic Design
Assuming you will be doing elastic analysis- no factor is required for nonlinear analysis- it depends on the design-code you are using. Find the attached document for an elaborate answer to your query. Effective stiffness for modelling concrete members C-StrucAnalysis-Wong-Jan17-1.pdf -
You already mentioned the reason in your earlier post. It can be put this way: the shear wall is a member whose stiffness in one direction is at least 20 times the stiffness in the other direction.
-
As per the requirements defined for column.
-
Yes, it should be treated as column.
-
If you are doing elastic analysis, then you need compressive stress, Elastic modulus, Poisson's ratio and density. You can put these properties to define the material in any software. If you want to do nonlinear analysis, then you can use the concrete model available in both software to represent the strut.
-
Design and Modelling of Elevator in ETABS
Badar (BAZ) replied to Engr. Salman's topic in Concrete Design
You can apply the load through a dummy( zero-weight & zero-stiffness) beams. Check the wall for shear and axial stresses. You can consult the wall-related chapter of 318-14 for corresponding design strengths. -
Design and Modelling of Elevator in ETABS
Badar (BAZ) replied to Engr. Salman's topic in Concrete Design
Multiply 7 tones by a factor of 1.5 to take into to the account the dynamic effect of that loading. Apply that loading either in the form of point load, or gravity-directed UDL, on area elements representing the elevator shaft. -
Find out the first order moment (The moment without considering P-delta effect)as well as the moment by considering the P-delta effect.