You can use section designer to model hollow column and can also create ramps for stairs using the extrude command. I think it is better to keep your model simple and exclude ramps whatsoever.
-
Yes you can. You can also use Section Designer if the column size is not regular.
-
It is the same as designing a column with a stair case inside it. Thanks.
-
Check the tutorials at: https://www.csiamerica.com/products/safe/watch-and-learn
-
Torsion: Reinforced Concrete Members
Ayesha replied to UmarMakhzumi's topic in Journal/ Articles/ Tutorials
You can let the main beam crack. You know the applied force and you can calculate the stress due to force and subsequent crack width.- 15 replies
-
- torsional stiffness of beams
- risa torsion design
- (and 8 more)
-
I haven't checked your model but here are a number of things to consider. 1. For 1, you can set torsional modifiers zero where you anticipate compatibility torsion. Check the link below: 2. You might want to check your applied load units as well as load combinations. Either, the error is correct or applied load, load combination or section size is incorrect.
- 2 replies
-
- beam and column design
- design revision
-
(and 1 more)
Tagged with:
-
Generally to keep construction simple, people go with maximum reinfo throughout unless the max reinfo is too big. If that is the case, they use additional bars at critical locations.
-
No, I have never seen this before.
-
Core Wall manual Design For Wind & EQ
Ayesha replied to Saiful Islam Zaber's topic in General Discussion
Details: https://www.amazon.ca/Reinforced-Concrete-Design-Tall-Buildings/dp/143980480X -
First analysis tells you how much you structure would displace under gravity load. Second order analysis considers the displacement under gravity and its consequences. In simple words, you are checking a displaced structure under the effect of gravity load.
- 2 replies
-
- second order analysis
- p-delta
-
(and 1 more)
Tagged with:
-
Can you share the error code or number?
-
Why do you want to do this?
-
Post tensioning effects on vertical elements
Ayesha replied to Syed Umair Haider's topic in Concrete Design
Can't we apply those forces manually on vertical supporting elements? -
How is that possible?
- 8 replies
-
- rcc
- property modifiers
-
(and 4 more)
Tagged with:
-
You can find time period for seismic analysis done through Equivalent Lateral Force procedure by printing the summary sheet.
-
MARBLE POWDER AS REPLACEMENT OF CEMENT IN CONCRETE
Ayesha replied to Engr. Muhammad Usman Khan's topic in General Discussion
Please post. -
MARBLE POWDER AS REPLACEMENT OF CEMENT IN CONCRETE
Ayesha replied to Engr. Muhammad Usman Khan's topic in General Discussion
Where are the the research details that show 10% marble powder strength increase? -
ETABS has a built in detailing feature. https://www.csiamerica.com/products/etabs/features Here are a few others. https://www.s-cube.in/ProductRCDC.aspx http://www.farasaeg.ir/etabsmate_en.htm http://zaxises.com/rcbeamdetailer.htm I have personally tried none of these so can't give you any expert advise about specific softwares.
- 3 replies
-
- structural drawing
- software
-
(and 2 more)
Tagged with:
-
Valid points but any requirements for shear and moment demand should be met by "increasing the thickness of foundation" rather than relying on a beam to do so. The reason being that foundation (in this case strip foundation) reinforcement and formwork requirements are very simple and less labour intensive. Introducing a beam would make it complicated and more costly and in some cases an overkill. Also beam foundation will have no significant affect on settlement as I believe settlement is a function foundation width and bearing pressure, which in both cases would be similar.
-
Differential settlement consideration for tie-beam is a good design practice. Good point.
-
I can't see any difference.
-
Engr Waqas has replied you well. Beams are beams and columns are columns. Do your structural analysis and design them for forces they will experience. Don't reduce any forces thinking that these beams are tie or plinth. Plus stop tagging people in your posts. That is very unprofessional.
-
Modeling of wall elements for stiffness consideration
Ayesha replied to Waqas Haider's topic in Seismic Design
For the case of frame structure, the key is to have free standing masonry, i.e. provide gaps b/w masonry and frame on sides (between masonry and frame column) and top (between masonry and frame beam) and have it anchored so that it doesn't fall incase of a seismic event (this is very important or the wall will fall down in case of a seismic event). You can also find the attached example useful in understanding how free standing masonry should be anchored to structural system. Masonry Veneer Shelf Angle Design.pdf