Jump to content

Search the Community

Showing results for tags 'Pre-engineered Buildings'.

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • General
    • Member Introduction
    • Shout Box
    • Students Zone
    • Engineering Marvels & Disasters
  • Civil/ Structural Engineering
    • General Discussion
    • Steel Design
    • Concrete Design
    • Seismic Design
    • Foundation Design
    • Software Issues
    • Journal/ Articles/ Tutorials
    • Spreadsheets & Softwares
  • Technical Support
    • Website Announcements/ Problems/ Login/ Registration Issues
  • PSX Stocks Investing's Topics
  • Parenting's Topics
  • Construction Consulting's Industrial Construction Project
  • Construction Consulting's Piling

Calendars

  • Community Calendar
  • Construction Consulting's Piling

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


Website URL


Skype


Location


University


Employer


Interests

Found 1 result

  1. Basic Building Parameters The basic parameters that define a pre-engineered building are: Building Width, Building Length, Building Height, Roof Slope, End Bay Length, Interior Bay Length, and Design Loads. BUILDING WIDTH: No matter what primary framing system is used, the building width is defined as the distance from outside of eave strut of one sidewall to outside of eave strut of the opposite sidewall. Building width does not include the width of Lean-To buildings or roof extensions. BUILDING LENGTH The longitudinal length of the building measured from out to out of end wall steel lines. BUILDING HEIGHT: Building height is the eave height which usually is the distance from the bottom of the main frame column base plate to the top outer point of the eave strut. When columns are recessed or elevated from finished floor, eave height is the distance from finished floor level to top of eave strut. ROOF SLOPE: This is the angle of the roof with respect to the horizontal. The most common roof slopes are 0.5/10 and 1/10. Any practical roof slope is possible. END BAY LENGTH: The distance from outside of the outer flange of endwall columns to center line of the first interior frame column. INTERIOR BAY LENGTH: The distance between the center lines of two adjacent interior main frame columns. The most common bay lengths are 6 m, 7.5 m and 9 m. DESIGN LOADS: Unless otherwise specified Steel pre-engineered buildings are designed for the following minimum loads: Roof Live Load: 0.57 kN/m2 Design Wind Speed: 110 km/h Design for snow loads, earth quake loads, collateral loads, crane loads or any other loading condition, if required must be specified. Source: zamilsteel.com
×
×
  • Create New...

Important Information

By using this site, you agree to our Terms of Use and Guidelines.