Jump to content

Search the Community

Showing results for tags 'rcc design'.

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • General
    • Member Introduction
    • Shout Box
    • Students Zone
    • Engineering Marvels & Disasters
  • Civil/ Structural Engineering
    • General Discussion
    • Steel Design
    • Concrete Design
    • Seismic Design
    • Foundation Design
    • Software Issues
    • Journal/ Articles/ Tutorials
    • Spreadsheets & Softwares
  • Technical Support
    • Website Announcements/ Problems/ Login/ Registration Issues
  • PSX Stocks Investing's Topics
  • Parenting's Topics
  • Construction Consulting's Industrial Construction Project
  • Construction Consulting's Piling

Calendars

  • Community Calendar
  • Construction Consulting's Piling

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


Website URL


Skype


Location


University


Employer


Interests

Found 5 results

  1. AOA everyone. I need some guidance regarding the construction of confined masonry directly over the frame structure i-e it should not be erected from foundation. What does your engineering judgement suggests? Is there any reference available on this particular thread? Thank you.
  2. Aslam o alikum every one, Dear seniors i am new to Etabs and i was designing a multi story plaza my beams and column failed i tried to revise the design by applying the bigger sections but still they don't satisfy These are the error i find in summery of designed section 1. For beams it says the shear stress due to shear force and torsion together exceeds maximum allowed 2. For columns it says reinforcing required exceeds the maximum allowed How can i revise the design and satisfy my sections. Kindly help me in it because increasing member size is not helping i am attaching my etabs project for your reference thank you. Plaza Design.rar
  3. Dear fellows! I have observed that some senior engineers have not been using stiffness modifiers in their designs. What is the concept behind i am not clear . As we design RC for strength, section is cracked and to cater for this cracked section, property modifiers are used as per ACI 318-11 10.10.4 (stiffness requirement) ACI 318-11 8.7 (stiffness requirement) UBC97 1630.1.2 (modelling requirement) so why whole section is considered in design. is there any other logic which i couldn't understand. Regards
  4. Structural engineer required in a consultants in clifton DHA karachi (opposite Ocean Mall) Engineer must having a valid pec registration. - should have skills on RCC design of multistory building structures - should have skills on design softwares ETABs, SAFE etc.. send your resume on consult.hiring2000@gmail.com with subject "Applied for Structural Engineer"
×
×
  • Create New...

Important Information

By using this site, you agree to our Terms of Use and Guidelines.