Jump to content

Search the Community

Showing results for tags 'ritz'.

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • General
    • Member Introduction
    • Shout Box
    • Students Zone
    • Engineering Marvels & Disasters
  • Civil/ Structural Engineering
    • General Discussion
    • Steel Design
    • Concrete Design
    • Seismic Design
    • Foundation Design
    • Software Issues
    • Journal/ Articles/ Tutorials
    • Spreadsheets & Softwares
  • Technical Support
    • Website Announcements/ Problems/ Login/ Registration Issues
  • PSX Stocks Investing's Topics
  • Parenting's Topics
  • Construction Consulting's Industrial Construction Project
  • Construction Consulting's Piling

Calendars

  • Community Calendar
  • Construction Consulting's Piling

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


Website URL


Skype


Location


University


Employer


Interests

Found 4 results

  1. Asalmualaikum all, Anyone know any example verified in SAP software regarding ritz analysis. I am looking for an example in which I can verify the results using Ritz and Eigen Value analysis. Thanks for the help
  2. Salam how do we compare the two? RSA and Ritz which analysis should be prefered in different cases Regards
  3. Dear Engineers; I had a headache from this problem : I run analysis in Etabs for a G+4 Project using Ritz so it runs okay. But I wished to convert some columns to shell elements instead of frame elements then I run the etabs but the response spectrum analysis could not start. when I look into "Last analysis Log..." I found the following : " The strum sequence check found 5 eigen values below the shift Ritz analysis requires All eigen values to be above the shift " Regards
  4. Dear Engineers; I had a headache from this problem : I run analysis in Etabs for a G+4 Project using Ritz so it runs okay. But I wished to convert some columns to shell elements instead of frame elements then I run the etabs but the response spectrum analysis could not start. when I look into "Last analysis Log..." I found the following : " The strum sequence check found 5 eigen values below the shift Ritz analysis requires All eigen values to be above the shift " Regards
×
×
  • Create New...

Important Information

By using this site, you agree to our Terms of Use and Guidelines.