Assalam o alaikum. My building has special moment frames and 3 to 4 shear walls. The bay where shear walls are placed, no column is in the bay and beams are coming directly at top of shear wall and for the very specific bay, slab is also resting directly at shear wall at that location. How to decide in which category, exactly, my structure comes? UBC structural systems are 1629.6 Structural Systems. 1629.6.1 General. Structural systems shall be classified as one of the types listed in Table 16-N and defined in this section. 1629.6.2 Bearing wall system. A structural system without a complete vertical load-carrying space frame. Bearing walls or bracing systems provide support for all or most gravity loads. Resistance to lateral load is provided by shear walls or braced frames. I think my structure does not lie in this category because majority of slab and walls are resting at beams connected with columns. Am i right? 1629.6.3 Building frame system. A structural system with an essentially complete space frame providing support for gravity loads. Resistance to lateral load is provided by shear walls or braced frames. Is this structure is where no lateral load is resisted by frame and shear walls resist lateral loads? How is it possible that no lateral load is resisted by frames? 1629.6.4 Moment-resisting frame system. A structural system with an essentially complete space frame providing support for gravity loads. Moment-resisting frames provide resistance to lateral load primarily by flexural action of members. If I have 7 bays in a direction at a grid and I have 5 to 6 grids in building. An only end grids have shear walls in one or two bays, Will it be considered as building MRF or Dual system? What is exact differentiation between them? 1629.6.5 Dual system. A structural system with the following features: 1. An essentially complete space frame that provides support for gravity loads. 2. Resistance to lateral load is provided by shear walls or braced frames and moment-resisting frames (SMRF, IMRF, MMRWF or steel OMRF). The moment-resisting frames shall be designed to independently resist at least 25 percent of the design base shear. 3. The two systems shall be designed to resist the total design base shear in proportion to their relative rigidities considering the interaction of the dual system at all levels. Is there any limit that at least this much of base shear must be resisted by shear wall to consider it as Dual system otherwise it is MRF? Thanks.
- 11 replies
-
- structural systems
- ubc 97
-
(and 1 more)
Tagged with: