The minimum amount and spacing of reinforcement to be used in structural floors, roof slabs, and walls for control of temperature and shrinkage cracking is given in ACI 318 or in ACI 350R. The minimum-reinforcement percentage, which is between 0.18 and 0.20%, does not normally control cracks to within generally acceptable design limits. To control cracks to a more acceptable level, the percentage requirement needs to exceed about 0.60% (REFRENCE ACI COMMITE REPORT 224R-01) So according to above statement , should we follow 0.60%, to be on more safe side??
- 12 replies
-
- minimum reinforcement
- water tight structures
-
(and 1 more)
Tagged with:
-
How to model a swimming pool at top roof of a building , assign water lood and combination according to ACI code
-
What are the load combinations for water tight structures like ETP etc??
-
Hi guys just to discuss with you my understanding of crack widths in Environmental structures according to ACI. --------------------------- Normal structures --------------------------- 1. ACI 318-95 based on statistical method of Gergely & Lutz 1968 limits Z based on exposure. We are calculating crack widths here. (Normal structures) 2. ACI 318-99 proposed limiting the spacing and removed actually calculating the width and also removed the exposure conditions. For example for beams and one-way slabs s (in) = 540/fs -2.5cc or in other words limiting the fs=0.6fy (For normal structures) 3. ACI 224R-01 references method 1 and 2 above and 3 european codes. The most confusing part is the table in which Nawy suggests 0.1mm crack width for water-tight structures. The whole document is for normal structures except this line. And people are following this line and refer to this document for water tight structures. I mean its just a suggestion and by the way this method 1 is obsolete now since ACI 318-99 (see point 2 above). --------------------------- Water tight structures --------------------------- 1. ACI 318-08 states clearly that for watertight structures ACI 350-06 codes should be used. 2. ACI 224.4R-13 also specifically states that for watertight structures walls in section 7.4, we should use ACI 350-06. 3. ACI 350-06 for water tight structures does not recommend calculating a number for crack width but rather limiting max steel stress in bars to be 20k ksi or fs=0.33fy for normal conditions. --------------------------------------------------------------------------------------------------------- To sum it up, Philosophy of crack width control is not to calculate probable crack widths but to limit the max stress in steel bars. For normal structures: fs=0.6fy and for water tight structures fs=0.33fy